R.A.C.E. Approved Continuing  Education Seminars in your area:

Basic Diagnostic Ophthalmology Exam Series:

1.) TBA

2.) TBA

3.) TBA

4.) TBA



Low Level Laser Therapy CE: 

1.) TBA

2.) TBA 

3.) TBA

4.) TBA 

Accurate and immediate bedside results without spending more.

The epoc™ point of care blood analysis system is the first and only wireless bedside testing solution to use Smart Card technology. This breakthrough technology provides state-of-the-art lab results directly to a hand-held Mobile Computer. It’s easy to use. It requires no refrigeration of consumables. It interfaces with your facility’s existing wireless system. And in most cases it does it all for less than you’re spending now waiting for lab results.

Accurate results in 30 seconds.

The quality of test results from the epoc system are equal to or better than the results generated by traditional blood gas or chemistry analyzers run in a laboratory. Why? Because, once fresh blood is passed across biosensors on the epoc test card, results are sent to your Mobile Computer in just 30 seconds. Other systems often require more time between sample acquisition, sample entry and analysis and can result in sample degradation and possibly compromised results.

Higher technology equals lower cost.

epoc is significantly more cost effective to implement and use than other POC systems. In fact, the operational costs for the epoc system are usually equal to (or less than!) the cost of testing with conventional analyzers. With epoc you will easily attain the recognized benefits of an improved critical care process without the theoretical implementation models that typically demand labor reductions and other operational changes to meet financial objectives.

Fast and easy.

Unlike other systems, epoc test cards have no refrigerated storage requirements. The cards can be placed at the patient bedside with the card reader, at the nurses’ station, in the operating suite–whenever and wherever it’s most convenient for the flow of patient care. All that’s required is a 100 microliter blood sample.

epoc eliminates errors.

Immediate introduction of a patient’s blood sample into an epoc test card minimizes pre-analytical sample handling errors. And because the complete test record is captured at the point of care, post-analytical errors are also reduced. The epoc system features bar code scanning for patient ID, operator ID and test card information–minimizing data entry and transcription errors. Automated monitoring of all steps in the testing process assures error detection and reduction.

epoc requires virtually no modification to your current procedures or model of care. It seamlessly integrates into your WLAN or mobile EMR solutions–or existing point of care testing installations. And epoc is expandable as future needs evolve. Additional card readers can be placed where needed, and can interact with an unlimited number of epoc Mobile Computers.

epoc fits your organization today — and tomorrow.

epoc easily fits into your clinical care process. With its small size and wireless capability, epoc keeps caregivers at the bedside where they are needed most, not running back and forth between a distant workstation or laboratory. It seamlessly integrates into your existing wireless network and easily interfaces into your hospital’s LIS/HIS system. Additional epoc readers can be placed where needed, and can interact with an unlimited number of epoc Mobile Computers.

 

epoc BGEM Test Card Analytes

 

 

 

Measurement
Parameters

Units

Range

pH pH units 6.5-8.0
pCO2
 Carbon Dioxide, Partial Pressure
mmHg 5-250
pO2
 Oxygen, Partial Pressure 
mmHg 5-750
Na+
Sodium 
mmol/L 85-180
K+
Potassium
mmol/L 1.5-12
Ca++
Ionized Calcium
mmol/L 0.25-4
Glu
Glucose 
mg/dL 20-700
Lac
Lactate 
mmol/L 0.30-20.00
Creatinine  mg/dL
Canine (0.5-1.3)
Feline (1.0-2.2)
Equine (0.4-2.2)
Chloride  (CI)   Canine (106-127)
Feline (112-129)
Equine (100-111)
Hct
Hematocrit
%PCV 10-75

 

Calculated
Parameters

Units

Range

cTCO2
Hemoglobin
mmol/L 1-85
cHCO3-
Actual Bicarbonate
mmol/L 1-85
BE(ecf)
Total Carbon Dioxide
mmol/L -30–+30
BE(b)
Base Excess of Extra Cellular Fluid
mmol/L -30–+30
cSO2
Base Excess of Blood
mmol/L 0-100
cHgb
Oxygen Saturation
mmol/L
3.3-25

 

 

 

 

Product Info Packet:

Copyright © 2005-2012 Dan Scott & Associates. All Rights Reserved.
5188 Hoover Gate Lane, Westerville, OH 43082
(614) 890-0370